INNOVATIVE SOLUTIONS FOR GREENER BUILDINGS
 

ECB Series : Application Specific Controllers

The following Distech Controls controllers are BTL listed as Application Specific Controllers (B-ASC) for applications from single duct VAV to small AHU systems.

All controllers are fully programmable using EC-gfxProgram, graphical programming interface.

VAV applications: ECB-VAV and ECB-VAVS Series
Terminal Unit Applications:  ECB-103 and ECB-203 Series
Communicating Thermostats: Allure ECB-STAT Series
 

asc
   
  VAV Applications: ECB-VAV and ECB-VAVS Series  
     
ECB-VAVS and ECB-VAV Series
• For applications from single duct to fan powered VAV with reheat and radiation heating
•
Pre-engineered configurable application selected from the EC-Smart-Vue or from EC-NetAX configuration pages for quick setup
•
On-board drift-free and zero calibrated flow sensor reducing air flow balancing time
•
Built-in brushless DC motor actuator with intelligent damper control algorithm for extended actuator lifecycle and fast air flow balancing
•
5 models to cost effectively address all VAV applications
•
Universal inputs and outputs for maximum installation flexibility
•
Built-in brushless DC motor actuator with intelligent damper control algorithm
•
Digital outputs (TRIAC) that support internal supply of 24 VAC, simplifying wiring of outputs such as floating actuators
•
15 VDC power supply to power 4-20mA transducers
•
1 calendar, 2 schedule, 8 loop (PID), and over 200 BACnet objects
•
Support of up to 4 EC-Smart-Vue communicating sensors
•
Open-to-Wireless: support of up to 18 wireless battery-less inputs
Click here for datasheet  
 
ECB-VAV
 
   
 
 
- Back to top -
  Terminal Unit Applications  
     
ECB-103
• For two pipe fan coil, chilled ceiling, heat pump, and unit ventilator applications
• 4 universal inputs 
• 4 digital outputs (TRIAC) that supports internal supply of 24 VAC, simplifying wiring of outputs such as floating actuators
• 2 universal outputs
•
15 VDC power supply to power 4-20mA transducers
•
1 calendar, 2 schedule, 8 loop (PID), and over 200 BACnet objects
•
Support up to 4 EC-Smart-Vue communicating sensors
•
Open-to-Wireless: support of up to 18 wireless battery-less inputs
Click here for datasheet
ECB-103
 
ECB-203
• For roof top, four pipe fan coil, chilled ceiling, heat pump, unit ventilator, and small AHU systems
• 6 universal inputs
• 5 digital outputs (TRIAC)
• 3 universal outputs
•
15 VDC power supply to power 4-20mA transducers such as duct static pressure, etc.
•
1 calendar, 2 schedule, 8 loop (PID), and over 200 BACnet objects
•
Support up to 4 EC-Smart-Vue communicating sensors
•
Open-to-Wireless: support of up to 18 wireless battery-less inputs
Click here for datasheet
ECB-203
- Back to top -
   Communicating Thermostats    
     
Allure ECB-STAT
• Communicating thermostat for heat pump, roof top, fan coil, and zoning applications
•
2 software configurable digital inputs
•
Up to 3 remote sensor inputs
• Built-in temperature sensor and relative humidity sensor in select models
• Built-in scheduler in select models
• Change set point configurations and schedule directly from the controller
• Standalone or networkable
• Set user and password for different access levels
•
Optional PIR for standby mode occupancy support and additional energy savings
Click here for datasheet Fan Coil Applications
Click here for datasheet Zoning Applications
Click here for datasheet Roof Top Applications with Humidity Control
Click here for datasheet Roof Top Applications
Click here for datasheet Heat Pump Applications
ECB-STAT
 
 
 
   
   
     
- Back to top -

 

Copyright © Distech Controls 2008 and Trademarks